Carrier

Carrier QSH High Static 12.4kW Ducted System

Model 42QSH125D8S-1

The 12.4kW Carrier QSH High Static Ducted (indoor 42QSH125D8S-1) is rated at 12.4kW cooling and sized for typical three-bedroom single-storey homes. As a guide it covers roughly 83 to 99m² of conditioned floor area, depending on zoning, insulation and ceiling height. It runs R32 refrigerant and carries Carrier’s 7 year residential parts and labour warranty. For more bedrooms or a larger floor plan, the 13.6kW is the next step up.

Part of the Carrier QSH High Static Ducted range, Carrier's ducted system line, in 5 sizes. Running costs below use the Sydney median rate; the Eastern Suburbs and Western Sydney pages cost systems on their own network tariffs. Check the size against your rooms, compare it with other 12.4 kW options, or ask about supply and installation.

All Carrier QSH High Static Ducted sizes
Supply & install pricing
Fixed price in writing before work starts
Request a quote
24/7 emergency repairs Manufacturer warranty + our workmanship warrantyPhotos & details get you a sharper price
Energy efficiencyRegistered: 38QSH125D8S-1/42QSH125D8S-1
3.5 starsCooling ratingSydney climate zone
2.5 starsHeating ratingSydney climate zone
950 kWhCooling energy / yearabout $315 at the Sydney median rate
1631 kWhHeating energy / yearabout $540 at the Sydney median rate
3.35AEERACOP 3.91
What it costs to run

About $855 a year at the current Sydney median electricity rate: $315 of cooling plus $540 of heating, from the official GEMS test figures.

The Carrier QSH High Static 12.4kW uses 950 kWh annually for cooling and 1631 kWh annually for heating, according to official GEMS test data for Sydney's climate zone. These figures are derived from standardised energy label testing and reflect the system's performance under defined conditions.

The unit holds a 3.5 star cooling efficiency rating and a 2.5 star heating efficiency rating for Sydney. Its rated cooling efficiency (AEER) is 3.35 and heating efficiency (ACOP) is 3.91. The system operates on R32 refrigerant. Running costs depend on your local electricity rate and how often you run the system.

Source: Australian GEMS registry · median of 170 Sydney residential tariffs, including GST · Refreshed monthly · Last updated October 2026

The details

Specifications

From the manufacturer’s published range data. We confirm the exact configuration when we quote.

About the Carrier QSH High Static Ducted range
Documentation
BrandCarrier
Model42QSH125D8S-1
SeriesCarrier QSH High Static Ducted
System typeDucted System
Capacity12.4 kW
RefrigerantR32
ESP (rated/max)up to 50 / 200 Pa
Power supply220-240V single phase
Warranty7 year parts & labour (residential)